Electrocoagulation/flotation process for removing copper from an aqueous environment
Scientific Reports volume 13, Article number: 13334 (2023) Cite this article
206 Accesses
3 Altmetric
Metrics details
The presence of copper in aqueous environments such as drinking water has led to several environmental effects, such as flavor and odor. The increase in Cu levels in ground and surface water has been mainly attributed to anthropogenic and natural sources. Consequently, this applied-analytical study aimed to investigate copper removal from urban drinking water through batch reactor electrocoagulation/flotation (ECF) with aluminum electrodes. The copper removal efficiency was evaluated under various operating conditions of current density (0.8–2.4 mA/cm2), initial concentration (1–100 mg/L), pH (3.5–10.5), and time (10–30 min). Cu was determined using the method outlined in the standard procedures (3500-Cu B at 4571 nm). The results indicated that increasing the current density from 0.8 to 2.4 mA/cm2 and the reaction time from 10 to 30 min improved Cu+2 removal efficiency (from 95 to 100%). In addition, the results demonstrated that Cu+2 reduction is 100% with an initial concentration of 100 mg/L, a pH of 7.5, a reaction time of 30 min, and an anode current density of 2.4 mA/cm2. The Taguchi method results for copper removal efficiency show that reaction time is the most significant variable. Furthermore, Cu removal kinetics models in an ECF reactor are second-order (R2 > 0.92). The Cu removal in the ECF reactor is due to redox and adsorption. Moreover, the operational costs of Cu treatment with Al electrode pairs are estimated to range from 8857 and 9636 Rial/kg of Cu removed. Thus, it can be concluded that the ECF process is very efficient in removing Cu from aqueous environments under optimum conditions.
Copper (Cu) is a ductile metal with extremely high electrical and thermal conductivity. Cu is an essential trace mineral for all living organisms because it is a key constituent of the respiratory enzyme complex cytochrome oxidase. The Cu element exists in Cu+1 and Cu+2 forms1,2. Cu is present in the liver, the muscle, and the bone. Cu compounds are currently utilized as bacteriostatic substances, fungicides, and wood preservatives. Furthermore, copper sulfate (CuSO4) is widely employed as an algicide in aquatic environments3, where the high concentration of Cu in treated drinking water causes adverse health effects such as anemia, eye and skin irritation, and damage to the human brain and heart organs4.
Various copper compounds are used in tumor treatment5. In addition, a known association has been evidenced between abnormal Cu serum levels and Alzheimer's disease (AD)6. The US Environmental Protection Agency (EPA) states that the maximum concentration level (MCL) for copper in drinking water is 1.3 mg/L7. Cu and Cu enzymes affect energy metabolism, oxidative detoxification, and mitochondrial respiration8, where Cu and other micronutrients, such as iron, are essential for preventing AD9. Furthermore, anthropogenic (wire and cable, electronics and related devices, architecture, antimicrobial applications, wood manufacturing, industrial, mining, and agricultural activities, and sewage discharge) and natural (corrosion of household plumbing systems, rock weathering, rock and soil erosion, and atmospheric deposition) sources account for the majority of the increase in Cu levels in ground and surface water10. Due to its negative effects on human health and aquatic ecosystems, Cu is particularly considered in industrial wastewater treatment, where membrane separation, ion exchange, chemical precipitation, electrochemistry, adsorption, and biotechnology are among the applications11.
According to a systematic review conducted in Iran, the Cu concentration in drinking water exceeds permissible limits in 7.69% of the performed studies12. Cu concentration in 8 samples out of 58 samples are above the allowable limit (2.99 mg/L) in the drinking water sources of Karaj city, Iran13. According to the research conducted in 6 storm water ponds in Florida, the concentration of copper in sediments is several times that of water14. The important inputs of Cu to freshwater are natural sources (3.7 ktpa), agriculture (1.8 ktpa), and runoff (1.8 ktpa) in European Union15. The range of dissolved copper concentration is 6.4–45.4 nM in coastal and estuarine waters in water from a high industrialized and urban coastal system16.
Conventional processes for heavy metal removal such as Cu include adsorption (such as tobacco stem biochar), biosorption (such as Moringa oleifera seed biomass), ion exchange (tert-butyl 2-(methylamino)-N-acetic acid functionalized chelating resin), chemical precipitation (such as lime, soda ash, sodium sulfide), electrochemical, electrodeposition, membrane filtration (such as polyvinylamine by polymer-enhanced ultrafiltration and flocculation) methods17,18,19,20,21,22,23. The increased production of chemical sludge and the high stability of chemical precipitation are two of its disadvantages10. According to the research conducted in 6 rainwater ponds in Florida, the concentration of copper in sediments is several times that of waterTherefore, the Cu removal method must be novel and cost-effective, whereas recent years have seen the implementation of advanced oxidation processes (AOPs) such as combined electrocoagulation and flotation (ECF) for the treatment of wastewater contaminated with salicylic acid24.
Although in the electrocoagulation (EC) process with alternating pulse current, electricity consumption and electrode consumption for coagulant production have not been completely eliminated as weak points of the process. However, these disadvantages have been mitigated compared to the coagulation process and EC with direct current. By electrolyzing a consumed anode electrode, the ECF method generates coagulating agents. The ECF process involves the use of electric current and air bubbles in order to electrolyze, flocculate, and float contaminants without having to add coagulations. Efficiency of EC process is enhanced with external aeration25. EC aeration system has more efficiency than EC unit due to producing homogenous conditions and enhancing oxidation reaction. Effective factors influencing the performance of EC and ECF include electrode geometry, electrode material, geometry current density, water quality, and turbidity concentration26. The advantages of removing Cu by the ECF process are that no chemical agents are required, the pollutant in the water is removed by gas bubbles generated during the process, and the treatment is clean because no anion, other than hydroxide, is added (OH−1). This technique is a promising alternative to chemical coagulation due to not using chemical substances. The following equations illustrate this ECF mechanism involving aluminum anode and cathode electrodes and this process leads to the removal of Cu through the three mechanisms of electrode oxidation, the production of gas bubbles, and the processes of floating and settling the formed clots:
Based on the research history, ECF process to remove Cu is done for the first time in Iran. The Cu value in drinking water sources exceeds permissible limits in some parts of Iran country. From the aspects of innovation, similarities and differences of this research with other researches, it is possible to examine various variables in a research such as examining the concentration of copper in different ranges (1–100 mg/L), optimizing the process, examining the kinetics of the process, examining the mechanism of process, cost calculation and, examining the electrode surface mentioned. This study sought to remove Cu from drinking water using an ECF batch reactor with aluminum (Al) electrodes. The variables investigated were Cu concentration, current density, pH, and reaction time.
The weight of the electrode was measured after washing with distilled water. In order to remove impurities from the surface of the electrodes, the electrode was pre-treated by being polished with abrasive paper, washed with detergent and tap water, and rinsed with deionized water. The cleaned electrode was subsequently dried before being submerged in water in the reactor27.
The batch ECF with monopole arrangement was a 10 × 6 × 6 cm (360 mL) glass vessel (Fig. 1). Al materials and Al were utilized as anode and cathode electrodes, respectively. Each electrode had an active surface area of 36 cm2 (9 × 4 × 0.1 cm). The distance between electrodes was adjusted to 2 cm. To determine the and effect of electrolysis on the Cu removal process, samples were exposed to varying Cu (Merck, Germany) concentrations (1–100 mg/L−1), current densities (0.8–2.4 mA/cm2), pH (approx. 3.5–10.5), and reaction times (10–30 min). Water samples were aerated using an air stone and an aerated jet pump (RS. Model 610, China). For each test, 200 mL of water samples were poured into the reactor. All tests were conducted at 20 °C in the laboratory. Chloride acid and sodium hydroxide solutions (0.1 N) (Merck, Germany) were used for pH adjustment.
The batch ECF.
All tests were performed in triplicate, and the mean data values were reported. The Cu oxide reduction potential (ORP), pH, and temperature of the water samples were determined after using ECF using a spectrophotometer (DR 5000, Hack, USA), an ORP meter (CG, Malaysia), and a pH meter (Hack, USA), respectively. Notably, Cu values were determined using prevalent standard procedures (3500-Cu B at 4571 nm)28.
The Cu removal percentage was calculated using Eq. (9)29:
where (\(R \left(\mathrm{\%}\right)\)) denotes the percentage of Cu, and (\({C}_{0}\) and \({C}_{t}\) in mg/L) represents the Cu value before and after treatment.
The operational cost required for Cu removal was calculated through Eq. (10)29:
where (Coperational in Rial kWh per kg of Cu removed) denotes operational cost, (\(C_{energy}\) in kWh/kg) represents the consumed electrical energy cost, and (\(C_{electrode}\) in Rial per kg of Cu removed) is the consumed electrode cost.
The electrical energy required for Cu removal was calculated by Eq. (11):
where \(EE{ }\left( {\frac{kWh}{{kg}}Cu\,removed{\text{\% }}} \right)\) denotes the consumed electrical energy cost, \(V\) represents the electrical voltage, (I, A) is the electrical current, and \(t\) (min) is time.
Electrodes were rinsed with distilled water for 1 min after conducting all tests resulted in removing of deposits from the surface of the electrodes.
Kinetics reaction models were calculated through Eqs. (12) and (13)30,31:
where \(C_{0} { }\) and \(C_{t}\) denote the concentration of Cu at the beginning and after time \(t\) of the reaction, respectively, \(K_{1}\) and \(K_{2}\) represent the first and second-order reaction constants, respectively.
The slopes of the plots \(\ln C_{t}\) versus \(t\) and \(\frac{1}{{C_{t} }}\) versus \(t\) were used to determine the values of K1 and K2.
In addition, the Taguchi model was utilized to represent the relationship between four operational variables and three levels of removal efficiency32.
The effect of Cu's initial concentration on the ECF process's removal efficiency is shown in Fig. 2. As evident, the removal efficiency increases as the concentration increases from 1 to 100 mg/L. In addition, as pH increases from 3.5 to 7, the removal percentage for 100 mg/L Cu concentration in the ECF reactor decreases from 99 to 100%, with a 30 min reaction time and 2.4 mA/cm2 current density (Table 1). Moreover, when the Cu concentration increases from 1 to 100 mg/L at a current density of 2.4 mA/cm2 and pH 7, the reaction time decreases from > 30 min to 30 min (Table 1).
Effect of initial Cu concentration on the removal efficiency of Cu (Experimental conditions: pH: 3.5–10.5; Temperature: 20 °C; Reaction time: 30 min; Current density 2.4 mA/cm2).
Initial pH values in ECF experiments ranged from 3.5 to 10.5 (Fig. 3). When the Cu concentration increased from 1 to 100 mg/L in the ECF, the mean Cu removal rose in the optimum pH 7 condition. A 100% reduction of Cu could be achieved in a batch mode with an initial concentration of 100 mg/L, a pH of 7, a reaction time of 30 min, and an anode current density of 2.4 mA/cm2. Increasing the pH of the solution up to 7 improved the degradation effect of this method. The optimum pH for reaching the Cu standard (1.3 mg/L) was 7.
Effect of pH on the efficiency of Cu removal (Experimental conditions: Concentration: 1–100 mg/L; Temperature: 20 °C; Reaction time: 30 min; Current density 2.4 mA/cm2).
Figure 4 illustrates the current density's effect on the ECF process's removal efficiency. The optimal current density for achieving the Cu standard (1.3 mg/L) is 1.6 mA/cm2 at pH 7. Copper removal efficiency decreases at lower current density, reaction time, and Cu concentration (Table 1 and Fig. 4). The effect of the current density on the surface morphology of Al electrodes was studied utilizing a scanning electron microscope (SEM). As can be seen, the electrode was subjected to relatively consistent corrosion after applying an electrical current (Fig. 5).
Effect of the current density of Cu removal (Experimental conditions: pH: 7; Temperature: 20 °C; Initial concentration: 100 mg/L; Reaction time: 10–30 min).
SEM images of Al electrodes a) Before; b) After (Experimental conditions: pH 7; Temperature 20 °C; Initial concentration 100 mg/L; ; Current density 2.4 mA/cm2; Reaction time: 30 min).
The Taguchi model was used to determine the optimal operational variable values. Taguchi model results for Cu removal efficiency indicate that reaction time is the most significant variable (Fig. 6).
The Taguchi model (Experimental conditions: Temperature: 20 ºC; pH: 3.5–10.5; Reaction time: 0–30 min, ; Initial concentration: 1–100 mg/L; Current density 0.8–2.4 mA/cm2).
The plots of the first- and second-order kinetics reaction models correspond to the Cu removal experimental data in the batch ECF reactor, indicating that the experimental data corresponds better to the second-order reaction model at pH 7 (Fig. 7). Cu's regression coefficient was calculated as R2 = 0.921 based on the fitted line. The apparent rate constant, K2, and the half-life time, t1/2, were calculated to be 0.29 min−1 and 2.4 min, respectively.
The plots of first- and second-order reaction models with the Cu removal experimental data in batch ECF reactor (Experimental conditions: Temperature: 20 ºC; pH: 7; Reaction time: 0–30 min).
According to optimal conditions (electrical current 0.03 A, electrical potential 30 V, reaction time 30 min, and water demand 40 l/day), the minimum operational cost of the ECF was calculated to be Cu concentration 100 mg/L with a removal efficiency of 100% (8857 = 160 (consumed electrode cost) + 8697 (consumed electrical energy cost)) and the maximum operational cost of the ECF was calculated to be Cu concentration 1 mg/L with a removal efficiency of 88% (9636 = 520 (consumed electrode cost) + 9116 (consumed electrical energy cost)).
The results indicate no correlation between Cu concentration and removal efficiency. When the Cu concentration increases from 1 to 100 mg/L at a current density of 2.4 mA/cm2, the reaction time of 30 min, and pH 7, the efficiency inecreases from 95.4% to 100%. Higher concentrations (100 mg/L) require less time to reduce (about 30 min), but higher initial concentrations (100 mg/L) necessitate a significant reduction in removal times (about 30 min). The efficiency starts to increase at higher concentrations at the beginning of the operation (99.1%). In contrast, the low concentration (10 mg/L) decreases the removal efficiency after the process (94.5%). This is explicable through the theory of dilute solution. Amooey et al. (2014) report comparable findings33. According to Hosseini et al. (2015), the removal efficiency of a concentrated solution (300 mg/L) is inferior to that of a diluted solution (2 mg/L)34.
The efficiency of the coagulation process can be improved by increasing the concentration of the pollutant used as a reactant in the process; doing so raises the chemical potential and, in other words, follows Luchatelier's principle. In addition, according to the collision theory, it will increase the speed. The increase in copper removal (100%) caused by an increase in current density (2.4 mA/cm2) is proportional to the decrease in time (about 30 min) attributable to the increased opportunity for adsorption/desorption of reactive material species and current blockage. Prasetyaningrum et al. (2021) also report increased pollutant removal due to increased concentration35. According to Kim et al. (2014), the removal efficiency of a concentrated solution (100 mg/L) is greater than that of dilute solutions (10 and 50 mg/L)36. But Moradi and Ashrafizadeh (2020) report deceasing nitrate removal due to increasing the initial concentration and increasing process duration37. The removal effectiveness improves as the reaction time increases. When the Cu concentration increases from 1 to 100 mg/L at a current density of 2.4 mA/cm2 and pH 7, the reaction time decreases from > 30 min to 30 min. This result is consistent with data previously published by Adamovic et al. (2015). They report that the highest copper removal efficiency (> 92.8%) is achieved after 5 min with an 8 mA/cm2 current density and aluminum electrodes38.
Depending on the pH, the ECF process produces different hydrogen (H2) concentrations from water as a flotation agent. These products play a crucial role in the ECF process for removing Cu concentrations. This effect results from the increased availability of OH− anion at a lower pH, which produces more H2 bubbles. The decrease in Cu removal at pH 10 (99.5%) is attributable to the anode's increased oxidation of hydroxide anion. The final pH indicates a slight decrease in basicity (pH > 8) due to the precipitation of insoluble hydroxide Cu(OH)2. Kim et al. (2020) observed that the formation of metal hydroxide is complex at acidic pH due to the formation difficulty of OH− anions39. Due to the formation of metal hydroxides during the ECF process, the environment's pH is optimal for removing copper. Due to the amphoteric behavior of Al(OH)3, acidic and basic conditions produce soluble Al3+ cations and Al (OH)2+ and monomeric anions Al(OH)4−, respectively. These organisms are ineffective for water purification. This result is consistent with Prasetyaningrum et al. (2019)40. Mota et al. (2015) observed that theoretically the pH of 8.0 is the best point for the Pb ECF during the first 20 min of flotation41.
Merma et al. (2020) report that monomeric anions Al(OH)4− are the major species at pH values greater than 9.542. Therefore it is concluded that the ECF reactor acts as a pH buffer. Consequently, pH adjustment is not required before treatment in practical applications. From the operational point of view, it is beneficial because there is no need to adjust the amount of pH and higher performance. According to Moussa et al. (2017), pH significantly impacts the efficiency of the EC process. Due to the high specific surface area, micro flocs of Al(OH)3 formed at a pH of 7, resulting in rapid Cu absorption43. Al has a point of zero charges (pHPZC) of 9.6, and Cu has an electronegativity of 1.7544. Therefore, the sediment charge at pH 7 is positive.
The applied current density is a key variable affecting the kinetic of Cu removal in ECF, as it regulates the amounts of anodic dissolution of electrodes acting as precipitating agents. This result is consistent with data previously published by Chen et al. (2018)45. With increasing current density (2.4 mA/cm2), the reaction time begins to decrease (about 30 min). The removal efficiency is proportional to the current density and reaction time. Due to the anode's consumption, the higher current density (2.4 mA/cm2) and reaction time improve the removal efficiency (100%) by increasing the formation of coagulants and bubbles in the reactor. Das and Nandi et al. (2019) report that the increased formation of coagulants due to a higher current density improves the removal efficiency46. Consequently, the density fluctuations of the current lead to the measurement of the Cu removal rate. pH and ORP changes are used to predict the metal forms formed in the ECF reactor. This study measures the initial and final pH and ORP values to investigate pH's and ORP's effect more effectively. The pH rises from 7.10 to 7.60 due to the formation of H2 gas and OH− anions at the cathode electrode. The ORP decreases from 80 to -200. Majlesiet al. (2016) report that increase in current density from 0.4 to 3.2 mA/cm2 increased nitrate removal efficiency from 55 to 96% under optimum conditions of time and pH during the ECF47.
In this study, the current density increased from 0.8 to 2.4 mA/cm2 with a 30 min reaction time, pH 7, and 100 mg/L Cu concentration. Beyazit (2014) evidenced that 100% of Cu removal is reached at a current density of 90 mA/m248. At a current density greater than 20 mA/cm2, the removal efficiency begins to decrease as the reactor temperature rises due to the disintegration of OH radicals49. According to Jafari et al. (2023), 90% turbidity removal is obtained at a current density of 0.0028 mA/cm2 after 30 min of operation. Prica et al. (2015) report that at a current density of 8 mA/cm2 and an operating time of 60 min, > 95% of Cu is removed50. The current density of 2.4 mA/cm2, which has an efficiency close to the optimal value while consuming less energy, was chosen for economic reasons. SEM shows the behavior of the electrodes during the process and to characterize the morphology and corrosion mechanism51. Based on the SEM results, systematic corrosion and indentations on the surface of the anode due to production of various aluminum hydroxides leads to forming aluminum nanostructures, which may alter the mechanism and kinetics of electron transfer and oxidation. In other hands, corrosion of the electrode over time is caused by the effect of the current density and the partial stripping of the metal ions of the aluminum electrode.
The objective of the optimization is to determine the optimal operating conditions for Cu removal from aqueous environments by the ECF process. The orthogonal array includes experimental combinations with equal probability and controllable factors52. The Taguchi model results for Cu removal efficiency indicate that reaction time (35%) is the most significant variable. According to Apaydin et al. (2020), the contributions of pH, current density, and reaction time to COD removal efficiency are, respectively, 79.35%, 6.45%, and 4.46%53. According to Ozyonar et al. (2017), current density contributes the least to color removal efficiency54. Kurtoglu Akkaya and Oden (2022) reported that reaction time and current density contribute the most to 4-chlorophenol removal efficiency55. Kashi (2017) reported that reaction time the most to was to phenanthrene removal efficiency56.
Vrsalovic et al. (2023) state that adding zeolite is the most effective factor for chemical oxygen demand removal57. The apparent rate constant, K2, and the half-life time, t1/2, are calculated to be 0.29 min−1 and 2.4 min, respectively. This result contradicts the EC experiments Mohammadlou et al. (2014) performed with iron-steel electrodes. They concluded that the CR degraded according to a first-order kinetic model58. Selim et al. (2017) concluded that the heavey metals incuding Cu+2 degraded according to a first-order kinetic model59.
Al+3 cations react with H2O and OH− anions to produce coagulant agents in the reactor during the ECF process, such as a monomeric (Al(OH)2+, Al(OH)22+, Al2(OH)24+, Al(OH)4−) and polymeric hydroxides (Al6(OH)153+, Al7(OH)174+, Al8(OH)204+, Al13O4(OH)247+, Al13(OH)345+). The significant adsorption capacity of these agents is one of their distinguishing characteristics. Consequently, these agents can form bonds with Cu during the ECF process. This result is consistent with data previously published by Khue et al. (2014)60. Cu removal in the ECF reactor is concluded to be related to redox and adsorption. Suspended aluminum hydroxides are capable of removing Cu from water through adsorption, co-precipitation, redox, and electrostatic attraction, followed by a coagulation/flotation process. In addition to hydroxide precipitation and absorption on the Al(OH)3, Al(OH)2+, and Al(OH)+ flocs, from the perspective of Cu, Cu is reduced via direct electro-reduction at the cathode and electrolysis deposition. Equation (14) illustrates the removal mechanisms:
Cu produced from the reaction is removed from water due to adsorbing on the aluminum cathode surface and precipitating with coagulants. Consequently, as concentrations increase (100 mg/L), operational expenses begin to diminish (8857). The current efficiency, a significant variable in the ECF reactor, is 190.6%. This result is consistent with data previously published by Kobya et al. (2010). Kobya et al. demonstrate that the calculated cost of treatment with an EC reactor is $1.05 m−3 for cadmium and $2.45 m−3 for nickel and cyanide61. Shah et al. (2017) demonstrate that calcuated cost of the experimental design about 4.486 US$/dm362.
This study examined the reduction of copper from urbane drinking water in an electrocoagulation/flotation reactor in a batch with monopolar aluminum electrodes connection mode. To this end, various operational factors' effects on process reduction efficiency were investigated. The tests yielded the following results:
Cu reduction is influenced by Cu concentration. According to the collision theory, increasing the concentration from 1 to 100 mg/L increases the removal efficiency.
Due to the formation of hydrogen (H2) from water as a flotation agent, the degradation effect of this method is highly pH-dependent and enhanced by a pH increase of up to 7.
The optimum current density for reaching the Cu standard (1.3 mg/L) is 1.6 mA/cm2. By increasing the formation of coagulants and bubbles, a greater current density improves the removal efficiency.
Operating time significantly affects Cu reduction throughout the process; for a given set of experimental conditions, Cu reduction improves with increasing reaction time.
Cu reduction during reactor operation follows a second-order rate equation.
The removal process is linked to the cathode's increasing reduction conditions due to hydrogen evolution. Cu is reduced via direct cathodic electroreduction and electrolysis deposition.
As Cu concentration increases, operational costs decrease. At higher concentrations, the trend slows down.
The fact that ECF proposes advanced technologies for water and wastewater treatment. However, this process is not yet fully optimized, and more research is required before it can be implemented globally as a safe water purification method. Among the research's strengths and innovations are investigating the cost of the process, presenting the mechanism, determining the level of importance of the variables affecting the removal efficiency, SEM of the electrode before and after the process, and reaction kinetics. Among the limitations of this research is the failure to investigate the removal efficiency of the ECF reactor in the presence of chemical variables of water quality; therefore, it is suggested that future studies investigate the effect of these variables on the removal efficiency and the intensification effect of the continuous and batch ECF reactor with other types of electrodes.
ECF is an efficient and practical method for achieving a high degree of Cu reduction from drinking water in batch and monopolar electrode connection mode and a promising method for treating Cu-contaminated drinking water.
The datasets generated and analyzed during the current study were available from the corresponding author on reasonable request.
Feng, W. et al. Effects of copper exposure on oxidative stress, apoptosis, endoplasmic reticulum stress, autophagy and immune response in different tissues of Chinese mitten crab (Eriocheir sinensis). Antioxidants 11, 2029 (2022).
Article CAS PubMed PubMed Central Google Scholar
Jamal, A. et al. Distribution and health risk assessment of heavy metals in soil surrounding a lead and zinc smelting plant in Zanjan Iran. Hum. Ecol. Risk Assess. Int. J. 25, 1018–1033 (2019).
Article CAS Google Scholar
Zhang, B.-H. et al. Algicidal activity of Streptomyces eurocidicus JXJ-0089 metabolites and their effects on Microcystis physiology. Appl. Environ. Microbiol. 82, 5132–5143 (2016).
Article ADS CAS PubMed PubMed Central Google Scholar
Fu, Z. et al. Copper and zinc, but not other priority toxic metals, pose risks to native aquatic species in a large urban lake in Eastern China. Environ. Pollut. 219, 1069–1076 (2016).
Article CAS PubMed Google Scholar
Tsvetkov, P. et al. Copper induces cell death by targeting lipoylated TCA cycle proteins. Science 375, 1254–1261 (2022).
Article ADS CAS PubMed PubMed Central Google Scholar
Choe, Y. M. et al. Association between copper and global cognition and the moderating effect of iron. Front. Aging Neurosci. 14 (2022).
Mallik, A. K. et al. Cu (II) removal from wastewater using chitosan-based adsorbents: a review. J. Environ. Chem. Eng., 108048 (2022).
Ji, P. et al. Potential of copper and copper compounds for anticancer applications. Pharmaceuticals 16, 234 (2023).
Article CAS PubMed PubMed Central Google Scholar
Ayton, S. et al. Regional brain iron associated with deterioration in Alzheimer’s disease: A large cohort study and theoretical significance. Alzheimers Dement. 17, 1244–1256 (2021).
Article PubMed PubMed Central Google Scholar
Rehman, M. et al. Copper environmental toxicology, recent advances, and future outlook: A review. Environ. Sci. Pollut. Res. 26, 18003–18016 (2019).
Article CAS Google Scholar
Liu, Y., Wang, H., Cui, Y. & Chen, N. Removal of copper ions from wastewater: A review. Int. J. Environ. Res. Public Health 20, 3885 (2023).
Article CAS PubMed PubMed Central Google Scholar
ParsiMehr, M., Hekmati, M. & Shayesteh, K. Investigation of heavy metals in drinking water: A systematic review in Iran. J. Adv. Environ. Health Res. 8, 216–224 (2020).
Google Scholar
Valaei, N., Nazariha, M., Dehghanifard, E. & Akbari, S. Concentration of heavy metals in drinking water sources of Karaj in 2017: A descriptive study. J. Rafsanjan Univ. Med. Sci. 18, 227–236 (2019).
Google Scholar
Lusk, M. G. & Chapman, K. Copper concentration data for water, sediments, and vegetation of urban stormwater ponds treated with copper sulfate algaecide. Data Brief 31, 105982 (2020).
Article PubMed PubMed Central Google Scholar
Comber, S. et al. Sources of copper into the European aquatic environment. Integr. Environ. Assess. Manag. (2022).
Braga, E. S. & Ricardo, R. D. Background concentration of copper and cadmium in water from a high industrialized and urban coastal system (Baixada Santista, Brazil)—contribution to a monitoring program. J. Geosci. Environ. Protect. 9, 132–150 (2021).
Article Google Scholar
Zhou, Z. et al. Effect of pyrolysis condition on the adsorption mechanism of lead, cadmium and copper on tobacco stem biochar. J. Clean. Prod. 187, 996–1005 (2018).
Article CAS Google Scholar
Nwagbara, V. U., Chigayo, K., Iyama, W. A. & Kwaambwa, H. M. Removal of lead, cadmium, and copper from water using Moringa oleifera seed biomass. J. Water Clim. Change 13, 2747–2760 (2022).
Article Google Scholar
Qiu, X., Hu, H., Yang, J., Wang, C. & Cheng, Z. Removal of trace copper from simulated nickel electrolytes using a new chelating resin. Hydrometallurgy 180, 121–131 (2018).
Article CAS Google Scholar
Chen, Q. et al. Comparison of heavy metal removals from aqueous solutions by chemical precipitation and characteristics of precipitates. J. Water Process Eng. 26, 289–300 (2018).
Article Google Scholar
Najafpoor, A. A., Davoudi, M. & Salmani, E. R. Optimization of copper removal from aqueous solutions in a continuous electrochemical cell divided by cellulosic separator. Water Sci. Technol. 75, 1233–1242 (2017).
Article CAS PubMed Google Scholar
de Morais Nepel, T. C., Landers, R., Vieira, M. G. A. & de Almeida Neto, A. F. Metallic copper removal optimization from real wastewater using pulsed electrodeposition. J. Hazard. Mater. 384, 121416 (2020).
Article Google Scholar
Huang, Y. et al. Removal of heavy metals from water using polyvinylamine by polymer-enhanced ultrafiltration and flocculation. Sep. Purif. Technol. 158, 124–136 (2016).
Article CAS Google Scholar
Ahmad, A., Priyadarshini, M., Das, I., Ghangrekar, M. M. & Surampalli, R. Y. Surfactant aided electrocoagulation/flotation using punched electrodes for the remediation of salicylic acid from wastewater. J. Environ. Chem. Eng. 11, 109049 (2023).
Article CAS Google Scholar
Kumar, A., Nidheesh, P. & Kumar, M. S. Composite wastewater treatment by aerated electrocoagulation and modified peroxi-coagulation processes. Chemosphere 205, 587–593 (2018).
Article ADS CAS PubMed Google Scholar
Khandegar, V. & Saroha, A. K. Effect of electrode shape and current source on performance of electrocoagulation. J. Hazard. Toxic Radioactive Waste 20, 06015001 (2016).
Article Google Scholar
Kashi, G. Optimization of electrochemical process for removing sulphate from drinking water by Taguchi model. Int. J. Curr. Res. 7, 17409–17414 (2015).
Google Scholar
Rice, E. W., Bridgewater, L. & Association, A. P. H. Standard methods for the examination of water and wastewater Vol. 10 (American public health association Washington, 2012).
Google Scholar
Giti, K. & Narges, J. Optimization electrophotocatalytic removal of acid red 18 from drinking water by the Taguchi model. Bul. Chem. Commun. 47, 179–186 (2015).
Google Scholar
Yousefi, M. et al. Comparison of LSSVM and RSM in simulating the removal of ciprofloxacin from aqueous solutions using magnetization of functionalized multi-walled carbon nanotubes: Process optimization using GA and RSM techniques. J. Environ. Chem. Eng. 9, 105677 (2021).
Article CAS Google Scholar
Yousefi, M., Nabizadeh, R., Alimohammadi, M., Mohammadi, A. A. & Mahvi, A. H. Removal of phosphate from aqueous solutions using granular ferric hydroxide process optimization by response surface methodology. Desalin Water Treat 158, 290–300 (2019).
Article CAS Google Scholar
Kashi, G. & Nourieh, N. Electrochemical process for removing nitrate from drinking water by Taguchi model. Desalination Water Treatment 281, 225–233 (2023).
Article CAS Google Scholar
Amooey, A. A., Ghasemi, S., Mirsoleimani-azizi, S. M., Gholaminezhad, Z. & Chaichi, M. J. Removal of Diazinon from aqueous solution by electrocoagulation process using aluminum electrodes. Korean J. Chem. Eng. 31, 1016–1020 (2014).
Article CAS Google Scholar
Hosseini, G., Maleki, A., Daraei, H., Faez, E. & Shahamat, Y. D. Electrochemical process for diazinon removal from aqueous media: design of experiments, optimization, and DLLME-GC-FID method for diazinon determination. Arab. J. Sci. Eng. 40, 3041–3046 (2015).
Article CAS Google Scholar
Prasetyaningrum, A., Ariyanti, D., Widayat, W. & Jos, B. Copper and lead ions removal by electrocoagulation: Process performance and implications for energy consumption. Int. J. Renewable Energy Dev. 10 (2021).
Kim, D.-G., Palacios, R. J. S. & Ko, S.-O. Characterization of sludge generated by electrocoagulation for the removal of heavy metals. Desalin. Water Treat. 52, 909–919 (2014).
Article Google Scholar
Moradi, M. & Ashrafizadeh, S. N. Nitrate removal from tapwater by means of electrocoagulation-flotation process. Sep. Sci. Technol. 55, 1577–1587 (2020).
Article CAS Google Scholar
Adamovic, S. et al. Feasibility of electrocoagulation/flotation treatment of waste offset printing developer based on the response surface analysis. Arab. J. Chem. 9, 152–162 (2016).
Article CAS Google Scholar
Kim, T., Kim, T.-K. & Zoh, K.-D. Removal mechanism of heavy metal (Cu, Ni, Zn, and Cr) in the presence of cyanide during electrocoagulation using Fe and Al electrodes. J. Water Process Eng. 33, 101109 (2020).
Article Google Scholar
Prasetyaningrum, A., Jos, B., Dharmawan, Y. & Praptyana, I. in J. Phys. Conf. Ser.. 012064 (IOP Publishing).
da Mota, I. D. O., de Castro, J. A., de Góes Casqueira, R. & de Oliveira Junior, A. G. Study of electroflotation method for treatment of wastewater from washing soil contaminated by heavy metals. J. Mater. Res. Technol. 4, 109–113 (2015).
Article Google Scholar
Merma, A. G., Santos, B. F., Rego, A. S., Hacha, R. R. & Torem, M. L. Treatment of oily wastewater from mining industry using electrocoagulation: fundamentals and process optimization. J. Market. Res. 9, 15164–15176 (2020).
CAS Google Scholar
Moussa, D. T., El-Naas, M. H., Nasser, M. & Al-Marri, M. J. A comprehensive review of electrocoagulation for water treatment: Potentials and challenges. J. Environ. Manage. 186, 24–41 (2017).
Article PubMed Google Scholar
Rahim, S. A., Hussain, S. & Farooqui, M. Binary complexes of nicotinic acid with transition metal ions in aqueous medium. Int. J. Chem. Sci. 12, 1299 (2014).
Google Scholar
Chen, X., Ren, P., Li, T., Trembly, J. P. & Liu, X. Zinc removal from model wastewater by electrocoagulation: Processing, kinetics and mechanism. Chem. Eng. J. 349, 358–367 (2018).
Article CAS Google Scholar
Das, D. & Nandi, B. K. Removal of Fe (II) ions from drinking water using Electrocoagulation (EC) process: Parametric optimization and kinetic study. J. Environ. Chem. Eng. 7, 103116 (2019).
Article CAS Google Scholar
Majlesi, M., Mohseny, S. M., Sardar, M., Golmohammadi, S. & Sheikhmohammadi, A. Improvement of aqueous nitrate removal by using continuous electrocoagulation/electroflotation unit with vertical monopolar electrodes. Sustainable Environ. Res. 26, 287–290 (2016).
Article CAS Google Scholar
Beyazit, N. Copper (II), chromium (VI) and nickel (II) removal from metal plating effluent by electrocoagulation. Int. J. Electrochem. Sci 9, 4315–4330 (2014).
Article Google Scholar
Jafari, E., Malayeri, M. R., Brückner, H. & Krebs, P. Impact of operating parameters of electrocoagulation-flotation on the removal of turbidity from synthetic wastewater using aluminium electrodes. Miner. Eng. 193, 108007 (2023).
Article CAS Google Scholar
Prica, M. et al. The electrocoagulation/flotation study: The removal of heavy metals from the waste fountain solution. Process Saf. Environ. Prot. 94, 262–273 (2015).
Article CAS Google Scholar
Dubent, S. & Mazard, A. Characterization and corrosion behaviour of grade 2 titanium used in electrolyzers for hydrogen production. Int. J. Hydrogen Energy 44, 15622–15633 (2019).
Article CAS Google Scholar
Yen, H. Y. & Lin, C. P. Adsorption of Cd (II) from wastewater using spent coffee grounds by Taguchi optimization. Desalin. Water Treat. 57, 11154–11161 (2016).
Article CAS Google Scholar
Apaydin, O. & Ozkan, E. Landfill leachate treatment with electrocoagulation optimization by using Taguchi method. Desalin. Water Treat 173, 65–76 (2020).
Article CAS Google Scholar
Ozyonar, F., Muratcobanoglu, H. & Gokkus, O. Taguchi approach for color removal using electrocoagulation with different electrode connection types. Fresenius Environ Bull 26, 7600–7607 (2017).
CAS Google Scholar
Akkaya, G. K. & Öden, M. K. Optimization of the effect of copper electrodes on the removal efficiency of 4-clorophenol from aqueous solution by electrocoagulation. Environ. Res. Technol. 5, 33–43 (2022).
Article Google Scholar
Kashi, G. Optimization of electrochemical process for phenanthrene removal from aqueous medium by Taguchi. Toxicol. Environ. Chem. 99, 772–782 (2017).
Article CAS Google Scholar
Vrsalovic, L. M. N., Svilovic, S. & Pavlinovic, A. Taguchi method in the optimization of municipal wastewater treatment by electrocoagulation integrated with zeolite. Energy Rep 8, 123–142 (2023).
Google Scholar
Mohammadlou, N., Rasoulifard, M. H., Vahedpour, M. & Eskandarian, M. R. The kinetic and thermodynamic study for decolorization of Congo red from aqueous solution using electrocoagulation process. J. Appl. Chem. Res. 8, 123–142 (2014).
Google Scholar
Selim, K., ElHosiny, F., Abdel Khalek, M. & Osama, I. Kinetics and thermodynamics of some heavy metals removal from industrial effluents through electro-flotation process. Colloids Surf. Sci 2, 47–53 (2017).
Google Scholar
Khue, V. A., Guo, L. T., Jun, X. X., Lin, Y. X. & Hao, P. R. Removal of copper and fluoride from wastewater by the coupling of electrocoagulation, fluidized bed and micro-electrolysis (EC/FB/ME) process. Am. J. Chem. Eng. 6, 86–91 (2014).
Article Google Scholar
Kobya, M., Demirbas, E., Parlak, N. & Yigit, S. Treatment of cadmium and nickel electroplating rinse water by electrocoagulation. Environ. Technol. 31, 1471–1481 (2010).
Article CAS PubMed Google Scholar
Shah, A. R., Tahir, H., Ullah, H. M. K. & Adnan, A. Optimization of electrocoagulation process for the removal of binary dye mixtures using response surface methodology and estimation of operating cost. Open J. Appl. Sci. 7, 458–484 (2017).
ADS Google Scholar
Download references
This research was conducted at an Environmental Health Engineering Laboratory. The author appreciates the funding and resources provided by the Water Purification Research Center and the Department of Environmental Health at Tehran Medical Sciences Branch, Islamic Azad University, Tehran, Iran.
Department of Environmental Health Engineering, Faculty of Health, Tehran Medical Sciences Branch, Islamic Azad University, Khaghani St., Shariati Ave, Tehran, Iran
Giti Kashi
Water Purification Research Center, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran
Giti Kashi
You can also search for this author in PubMed Google Scholar
G.K.: Conceptualization, Methodology, Investigation, Formal analysis, Writing–original draft, Writing–review & editing, Supervision.
Correspondence to Giti Kashi.
The author declares no competing interests.
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
Reprints and Permissions
Kashi, G. Electrocoagulation/flotation process for removing copper from an aqueous environment. Sci Rep 13, 13334 (2023). https://doi.org/10.1038/s41598-023-40512-y
Download citation
Received: 02 June 2023
Accepted: 11 August 2023
Published: 16 August 2023
DOI: https://doi.org/10.1038/s41598-023-40512-y
Anyone you share the following link with will be able to read this content:
Sorry, a shareable link is not currently available for this article.
Provided by the Springer Nature SharedIt content-sharing initiative
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.